YASKAWA SGD7S Product Manual page 359

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

 Using the Torque Reference as the Mode Switching Condition (Default Setting)
When the torque reference equals or exceeds the torque set for the mode switching level for
torque reference (Pn10C), the speed loop is changed to P control.
The default setting for the torque reference level is 200%.
Speed reference
Speed
Torque reference
+Pn10C
Torque reference 0
- Pn10C
PI control
PI
P
 Using the Speed Reference as the Mode Switching Condition
• Rotary Servomotors
When the speed reference equals or exceeds the speed set for the mode switching level for a
speed reference (Pn10D), the speed loop is changed to P control.
Speed reference
Speed
Pn10D
PI
P control
• Linear Servomotors
When the speed reference equals or exceeds the speed set for the mode switching level for a
speed reference (Pn181), the speed loop is changed to P control.
Speed reference
Speed
Pn181
PI
P control
Motor speed
Time
PI control
P
Motor speed
Time
PI control
Motor speed
Time
PI control
8.13 Manual Tuning
8.13.2 Compatible Adjustment Functions
8
8-93

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents