Parameter
Name
No.
Base Current Derating
Pn52C
2
at Motor Overload
Detection
Program Jogging-
2
Related Selections
Program Jogging Operation Pattern

n.
X
Pn530

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Program Jogging Travel
Pn531
4
Distance
Program Jogging Move-
Pn533
2
ment Speed
Program Jogging Accel-
Pn534
2
eration/Deceleration
Time
Program Jogging Wait-
Pn535
2
ing Time
Program Jogging Num-
Pn536
2
ber of Movements
Analog Monitor 1 Offset
Pn550
2
Voltage
Analog Monitor 2 Offset
Pn551
2
Voltage
Analog Monitor 1 Mag-
Pn552
2
nification
Analog Monitor 2 Mag-
Pn553
2
nification
Power Consumption
Pn55A
2
Monitor Unit Time
Residual Vibration
Pn560
2
Detection Width
Overshoot Detection
Pn561
2
Level
Pn581
2
Zero Speed Level
Setting
Setting
Range
Unit
10 to 100
1%
0000 to
0005
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
0
movements in Pn536
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
1
movements in Pn536
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
movements in Pn536
2
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
movements in Pn536
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
movements in Pn536
3
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
movements in Pn536
(Waiting time in Pn535 → Forward by travel distance in Pn531 → Waiting time
in Pn535 → Reverse by travel distance in Pn531) × Number of movements in
4
Pn536
(Waiting time in Pn535 → Reverse by travel distance in Pn531 → Waiting time
in Pn535 → Forward by travel distance in Pn531) × Number of movements in
5
Pn536
1 refer-
1 to
ence
1,073,741,824
unit
Rotary:
1 min
Direct
1 to 10,000
Drive:
0.1
-1
min
2 to 10,000
1 ms
0 to 10,000
1 ms
0 to 1,000
Times
-10,000 to
0.1 V
10,000
-10,000 to
0.1 V
10,000
-10,000 to
× 0.01
10,000
-10,000 to
× 0.01
10,000
1 to 1,440
1 min
1 to 3,000
0.1%
0 to 100
1%
1 to 10,000
1 mm/s
13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
100
All
restart
Immedi-
0000
All
ately
Immedi-
32768
All
ately
-1
Immedi-
500
Rotary
ately
Immedi-
100
All
ately
Immedi-
100
All
ately
Immedi-
1
All
ately
Immedi-
0
All
ately
Immedi-
0
All
ately
Immedi-
100
All
ately
Immedi-
100
All
ately
Immedi-
1
All
ately
Immedi-
400
All
ately
Immedi-
100
All
ately
Immedi-
20
Linear
ately
Continued on next page.
Classi-
Refer-
fication
ence
page
Setup
5-39
page
Setup
7-14
page
Setup
7-14
page
Setup
7-14
page
Setup
7-14
page
Setup
7-14
page
Setup
7-14
page
Setup
9-6
page
Setup
9-6
page
Setup
9-6
page
Setup
9-6
Setup
page
Setup
8-56
page
8-24,
Setup
13
page
8-35
page
Setup
6-8
13-29

Hide quick links:

Advertisement

Table of Contents
loading