Wiring The Power Supply To The Servopack; Terminal Symbols And Terminal Names - YASKAWA SGD7S Product Manual

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

4.3 Wiring the Power Supply to the SERVOPACK

4.3.1 Terminal Symbols and Terminal Names

4.3

Wiring the Power Supply to the SERVOPACK

4.3.1

Terminal Symbols and Terminal Names

Use the main circuit connector on the SERVOPACK to wire the main circuit power supply and
control circuit power supply to the SERVOPACK.
The SERVOPACKs have the following four types of main circuit power supply input specifica-
tions.
• Three-Phase, 200-VAC Power Supply Input
Terminal
Symbols
L1, L2, L3
L1C, L2C
B1/ , B2, B3
1,
4-12
 Wire all connections correctly according to the following table and specified reference infor-
mation. There is a risk of SERVOPACK failure or fire if incorrect wiring is performed.
Terminal Name
Main circuit power supply
input terminals for AC
power supply input
Control power supply termi-
nals
Regenerative Resistor termi-
nals
DC Reactor terminals for
power supply harmonic
2
suppression
CAUTION
Specifications and Reference
Three-phase, 200 VAC to 240 VAC, -15% to +10%, 50 Hz/60
Hz
Single-phase, 200 VAC to 240 VAC, -15% to +10%, 50 Hz/60
Hz
4.3.5 Wiring Regenerative Resistors on page 4-23
 For SGD7S-R70A, -R90A, -1R6A, and -2R8A
If the regenerative capacity is insufficient, connect an Exter-
nal Regenerative Resistor between B1/
The External Regenerative Resistor is not included. Obtain it
separately.
 For SGD7S-3R8A,- 5R5A, -7R6A, -120A, -180A, -200A,
and -330A
If the internal regenerative resistor is insufficient, remove the
lead or short bar between B2 and B3 and connect an Exter-
nal Regenerative Resistor between B1/
The External Regenerative Resistor is not included. Obtain it
separately.
 For SGD7S-470A, -550A, -590A, and -780A
Connect a Regenerative Resistor Unit between B1/
B2. Obtain a Regenerative Resistor Unit separately. These
models do not have a B3 terminal.
4.3.6 Wiring Reactors for Harmonic Suppression on page 4-
25
These terminals are used to connect a DC Reactor for power
supply harmonic suppression or power factor improvement.
None. (Do not connect anything to this terminal.)
and B2.
and B2.
and

Hide quick links: