7.1 Flow of Trial Operation

7.1.2 Flow of Trial Operation for Linear Servomotors

7.1.2

Flow of Trial Operation for Linear Servomotors

The procedure for trial operation is given below.
• Preparations for Trial Operation
Step
1
2
3
4
5
6
7-4
Meaning
Installation
Install the Servomotor and SERVOPACK
according to the installation conditions. First,
operation is checked with no load. Do not
connect the Servomotor to the machine.
Wiring and Connections
Wire and connect the SERVOPACK. First,
Servomotor operation is checked without a
load. Do not connect the CN1 connector on
the SERVOPACK.
Confirmations before Trial Operation
Power ON
Setting Parameters in the SERVOPACK
No. of Parameter to
Step
Set
5-1
Pn282
5-2

5-3
Pn080 = n.
X

5-4
Pn080 = n.
X
5-5
Pn50A = n.X
5-6
and Pn50B =
n.X
5-7
Pn483, Pn484
Setting the Origin of the Absolute Linear
Encoder
Note: This step is necessary only for an Absolute
Linear Servomotor from Mitutoyo Corpora-
tion.
Chapter 3 SERVOPACK Installation
Chapter 4 Wiring and Connecting SERVOPACKs
7.2 Inspections and Confirmations before Trial Opera-
tion on page 7-6
Description
Set this parameter only if
Linear Encoder
you are using a Serial Con-
Scale Pitch
verter Unit.
Writing Parameters
Set this parameter only if
to the Linear Servo-
you are not using a Serial
motor
Converter Unit.
Motor Phase
Sequence Selec-
tion
Polarity Sensor
Selection
This step is necessary only
Polarity Detection
for a Linear Servomotor with
a Polarity Sensor.
Overtravel Signal
Allocations
Force Control
5.17.2 Setting the Origin of the Absolute Linear
Encoder on page 5-49
Reference
Remarks
Reference
page 5-16
page 5-17
page 5-21
page 5-23
page 5-24
page 5-27
page 6-27

Hide quick links:

Advertisement

Table of Contents
loading