2
Technical Explanation > Main Controller > Security > Security features(encryption key and certificate, password protection)
4. Disable the feature
To set "OFF" for the TPM setting, execute [Initialize All Data / Settings].
Caution: Points to note when disabling functionality
To disable the use of TPM, all data and settings should be initialized. If this is executed,
user information saved in the FLASH is totally cleared. Ensure to back up the data
before disabling TPM settings.
2
Technical Explanation > Main Controller > Security > Security features(encryption key and certificate, password protection)
List of data to be cleared
• Data saved in Inbox (Fax Box/ System Box)
• Destination data registered in Address Book
• Read mode registered using Send function
• Mode memory registered using Copy/ Box function
• MEAP applications and their license files
• Data saved using MEAP applications
• Password for MEAP SMS (Service Management Service)
(The password is returned to default if any change is made.)
• User authentication information registered by local device authentication via SSO-H (Single
Sign-On H)
• Unsent documents (documents for scheduled transmission and reserved transmission)
• Job logs
• Contents set in Setting / Registration
• Image-composite registration form
• Registered transfer settings
• Key pair and server certificate registered in Management Setting (Setting/ Registration) >
[Device Management] > [Certificate Settings]
F-2-54
Steps of data restoration after recovery
The restoration process triggers Setting/ Registration > Management Setting > Data
Management > Import/ Export > Import/ Export Setting/ Registration on the UI.
The data listed below cannot be restored, thus should be set again.
2-40
2-40