interface increases beyond the configured threshold, the traffic will be dropped. Therefore,
the rate of multicast traffic will be limited to the configured threshold.
Default
5
Format
storm-control multicast level <0-100>
Mode
Global Config
no storm-control multicast level
This command sets the multicast storm recovery threshold to the default value for all
interfaces and disables multicast storm recovery.
Format
no storm-control multicast level
Mode
Global Config

storm-control multicast rate (Global)

Use this command to configure the multicast storm recovery threshold for all interfaces in
packets per second. If the mode is enabled, multicast storm recovery is active, and if the rate
of L2 broadcast traffic ingressing on an interface increases beyond the configured threshold,
the traffic is dropped. Therefore, the rate of multicast traffic is limited to the configured
threshold.
Default
0
Format
storm-control multicast rate <0-14880000>
Mode
Global Config
no storm-control broadcast rate
This command sets the broadcast storm recovery threshold to the default value for all
interfaces and disables broadcast storm recovery.
Format
no storm-control broadcast rate
Mode
Global Config

storm-control unicast

This command enables unicast storm recovery mode for an interface. If the mode is enabled,
unicast storm recovery is active, and if the rate of unknown L2 unicast (destination lookup
failure) traffic ingressing on an interface increases beyond the configured threshold, the traffic
will be dropped. Therefore, the rate of unknown unicast traffic will be limited to the configured
threshold.
Default
disabled