Field
Description
Receiver Index
Enter the sFlow Receiver associated with the sampler/poller. A value of zero (0) means
that no receiver is configured. The range is 1-8. The default is 0.
Poll Interval
Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter
sampling. When set to zero (0), all the poller parameters are set to their corresponding
default value. The range is 0-86400. The default is 0. A value of N means once in N
seconds a counter sample is generated.
no sflow poller
Use this command to reset the sFlow poller instance to the default settings.
Format
no sflow poller {<rcvr-indx> | interval <poll-interval>}
Mode
Interface Config

show sflow agent

The sFlow agent collects time-based sampling of network interface statistics and flow-based
samples. These are sent to the configured sFlow receivers. Use this command to display the
sFlow agent information.
Format
show sflow agent
Mode
Privileged EXEC
Field
Description
sFlow Version
Uniquely identifies the version and implementation of this MIB. The version string must
have the following structure: MIB Version; Organization; Software Revision where:
• MIB Version: '1.3', the version of this MIB.
• Organization: Netgear.
• Revision: 1.0
IP Address
The IP address associated with this agent.
Example: The following shows example CLI display output for the command.
(switch) #show sflow agent
sFlow Version.................................. 1.3;Netgear;1.0
IP Address..................................... 10.131.12.66