2.2.5.8

set inlinepower assigned

Use this command to manually assign Power Sourcing Equipment (PSE) power to a module in the
chassis.
set inlinepower assigned power-value slot-number
NOTE: If the total power wattage value set with this command is greater that the
maximum power percentage specified with the set inlinepower available command
(Section
2.2.5.4), a warning will display. If the user opts to execute these parameters, a
ratio of assigned power will be applied to each module. Refer to the show inlinepower
output
(Section
Syntax Description
power-value
slot-number
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to assign 200 watts of power to the module in slot 1:
Matrix(rw)->set inlinepower assigned 200 1
2.2.5.1) for a sample warning message.
Specifies a power value in watts.
Specifies a module slot location for the power assignment.