11.2.6.15 set timezone

Use this command to set the SNTP time zone name and the hours and minutes it is offset from
Coordinated Universal Time (UTC).
set timezone name [hours] [minutes]
Syntax Description
name
hours
minutes
Command Defaults
If offset hours or minutes are not specified, none will be applied.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the time zone to EST with an offset of minus 5 hours
Matrix(rw)->set timezone ETS -5 0
Specifies the time zone name.
(Optional) Specifies the number of hours this timezone will
be offset from UTC. Valid values are minus 12 (-12) to 12.
(Optional) Specifies the number of minutes this timezone
will be offset from UTC. Valid values are 0 to 59.
Matrix DFE-Platinum and Diamond Series Configuration Guide
Logging And Network Management Command Set
Configuring Simple Network Time Protocol (SNTP)
:
11-137