Edge Pitch; Step 1: Setting The Edge Detection Conditions - Omron F160 Operation Manual

Vision sensor
Hide thumbs Also See for F160:
Table of Contents

Advertisement

Edge Pitch

SeeAlso
3-8

Edge Pitch

SeeAlso
Operational Flow
3-8-1

STEP 1: Setting the Edge Detection Conditions

Measurement conditions
Target color
Mode
The Judgement Conditions Settings Screen will be displayed.
Judgement coordinate
Density average :
[ 0.000 : 255.000]
Density deviation : 31.376.
[ 0.000 : 255.000] :
End
2.
Make the settings for each item.
Refer to page 29 for details on inputting values.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Use the following procedure to find edges through density variations and
obtain the number of objects, width, and pitch.
Refer to page 10.
STEP 1
STEP 2
Set edge
Draw the
detection
measurement
conditions.
region.
Set the conditions for the edge search.
: White
: Normal
End
Normal: For measurement objects with a width and
Fine:
39.945
STEP 3
Set
judgement
conditions.
Target color for counting edges: White or black
separation of 2 pixels or more.
For stable measurement of objects with
smaller widths and separation than normal.
Section 3-8
(If required)
STEP 4
STEP 5
Change
Set
detailed
coordinate
conditions.
mode.
121

Advertisement

Table of Contents
loading