d-lab.2, d-lab.2plus, netlab.2plus: Operation
8.4.9

Cleaning the Filters in the ASTOR and Water Inlets

ASTOR: AgfaPhoto Stabilizer Tank Overflow Reduction
Purpose:
To ensure optimum processing quality.
1
2
3
dlab2513
AgfaPhoto
1 ASTOR
2 Water
3 Water tank cover
Open the door right of the docking station
(press the snap lock: middle left).
The water tank cover (3) must be closed.
Close the drain cocks of the three inlets.
Unscrew the cap nuts (1, 2) and carefully
remove them: they are full of liquid.
Remove the filters and rinse them in fresh
water.
Insert the filters again:
do not mix up the ASTOR filter (1) with the
water filters (2)!
Open the drain cocks again.
Note
Make sure that the shut-off tap is tight on the
housing (may move up during turning). If the
tap is not correctly mounted there is a risk of
stabilizer (STB) leaking from the Astor tank.
Close the door.