8.7.3

Emptying the Effluent Tanks

As soon as one of the effluent tanks is full, a message in the status bar on the screen
indicates that these tanks must be emptied.
Production can continue until an error message is displayed on the screen. In this case
printing is automatically interrupted. After the tanks have been emptied printing is
automatically resumed.
Special tools
– Hose
– Container with lid
(the volume of the tanks is 10 liters each; i.e. 20 l volume are needed for both)
CAUTION!
Observe the safety instructions for the handling of chemicals (see
Information
in Chapter 3).
Note
The effluent tanks combine the overflow of all processing tanks. Therefore there is no
need to drain the chemicals separately into the disposal tanks.
2
dlab2601
8-60
2005-05-01 / PN 04092_01
1
d-lab.2, d-lab.2plus, netlab.2plus: Operation
Safety
Empty a full tank:
Open the bottom left front door of the Paper
Processor.
Place the container under the tap (1); if it is
not possible to place the container under the
tap, attach a hose to the tap (1) and insert it
in the container.
Open the tap and empty the tank.
CAUTION!
Do not open the drain cocks, which are in
vertical position on the right side. They
are used to empty the processing tanks
CD, BX and SB1 to SB4, e.g. when a
completely new tank solution must be
filled into a single tank or all tanks.