Calibrating A New Paper Configuration Or Changing The Emulsion (Master Paper) - AgfaPhoto d-lab.2 8060/260 Operation Manual

Table of Contents

Advertisement

d-lab.2, d-lab.2plus, netlab.2plus: Operation
5.2.6
Calibrating a New Paper Configuration or Changing the Emulsion
(Master Paper)
Calibrating the master paper in case of emulsion changes
The following steps are required (further information see
Printing an MBL Test
in this chapter):
Calibration of a new paper configuration as master paper (= defining another paper configuration as master
paper)
The following steps are required (further information see
Printing an MBL Test
in this chapter):
Note
If the old emulsion was used up before an MBL could be printed, the calibration of the
new paper can only be started with a PBL. Usually this requires a complete new
Complete New Calibration
calibration (see
Without this new calibration there may be a deviation between the master paper and
all other papers. If this is the case, a complete new calibration is required.
In the following cases a new calibration is probably not required:
The last MBL with the old emulsion was made no more than a few hours ago.
The production during the last hours was stable and excellent quality.
AgfaPhoto
Printing a PBL Test
Print the MBL on the previous (old)
emulsion:
This provides for a calibrated condition of the
machine.
Right afterwards print a PBL with laser
point for the master paper with the new
emulsion.
Printing a PBL Test
Print an MBL on the previous master paper:
This provides for a calibrated condition of the
machine.
Change the definition of the master paper.
And right afterwards print a PBL with laser
point on the new master paper.
in this chapter).
2005-05-01 / PN 04092_01
and
and
Tests