General Description, Work Routines and Operation
2.5.4

Switching the Machine On and Off with the Main Breaker

CAUTION!
Only use the main breaker in emergencies to switch off the machine.
In normal operation always use the routine End of work > Shutdown to switch
off the machine (see
off the main breaker (1)!
If for technical reasons it is necessary to switch off the machine completely, e.g. for
longer down times (see
or for changing the chemicals (see
machine first as described in
off the main breaker.
If the machine is switched off with the main breaker without shutdown, this may
– (applies only to d-lab.2 with gas laser, Type 8060/260 and d-lab.2plus with gas laser, Type
8060/261)
reduce the service life of the blue/green laser considerably (failure of after-cooling).
cause problems with the main computer; the operating system may have to be
reinstalled,
cause paper jams if not all prints have left the Paper Processor.
If the machine was switched off via the main breaker wait at least one minute before you
switch on again. Otherwise the hard disc of the main computer may get damaged.
2-20
2005-05-01 / PN 04092_01
End of Work and Shutdown
Chapter 11), for some maintenance routines (see
Changing chemicals
End of Work and Shutdown
d-lab.2, d-lab.2plus, netlab.2plus: Operation
in this chapter); do not switch
Chapter 8)
in Chapter 3), shut down the
in this chapter, and then switch