status data-module
Output
For the following output example, the command that was entered is "status
data-module 301".
status data-module 301
Data Ext/Stn Ext for Stn DM: 301
Port/Channel Number: 01C1103
CF Destination Ext:
Connected Ports:
Field descriptions
Data Ext/Sta Ext
for Stn DM
Port/Channel
Number
Service State
CF Destination Ext
Maintenance Busy?
Connected Ports
555-233-123
DATA-MODULE STATUS
Service State: out-of-service
Maintenance Busy? no
The data module extension number. The DTDM is an
exception: the connected station extension is shown.
The port location of the data module
(cabinet-carrier-slot-circuit). If the data module specified is a
data channel, the channel number is shown instead.
This entry displays the status of the data module; valid states
are:
— In-service/idle
— The data module is present but not in use.
— In-service/active
— The data module is present and is in use.
— Out-of-service
— The data module has been removed from service
— Disconnected
— The data module no longer appears to be present
This entry displays the call forwarding destination, if any, of
the station.
Whether maintenance is testing the object, "yes" or "no".
Port locations to which the data module is connected
(cabinet-carrier-slot-circuit).