8.4 Data Transmission Protocols

8.4.1 Selection of Transmission Protocols

8 – 20
The operating modes are assigned the following transmission protocols:
Operating modes
FE1 and FE2
EXT1, EXT2, EXT3
LSV2
The following applies to all data transmission protocols except LSV2:
If an incoming file is already stored in the TNC, the TNC will ask you whether
you really wish to overwrite this file:
7 7 7 7
Press a soft key to continue the transmission.
If you attempt to overwrite a write-protected file, the TNC displays the error
message Protected file!:
7 7 7 7
Press the ADDITIONAL FUNCTION UNPROTECT soft key to cancel write-
protection and continue the transmission.
If a file has been read out and the data transfer menu has been terminated
with the END key, the TNC outputs the characters <EXT> and <EOT>.
If a transmission is terminated with the END key, the error message "Program
incomplete" is issued.
Transmission protocol
Select a protocol with BCC and with fixed
control characters
1 start bit, 7 data bits, 1 stop bit
Select data format and transmission protocol
using machine parameters
Start this protocol from a PC or from the TNC.
The protocol runs in the background of the
TNC.
HEIDENHAIN Technical Manual TNC 426, TNC 430