2.1
Specific data for TNC 151 B/TNC 155 B
Control inputs
Potential-free
opto-couplers
(switched into groups)
Operating voltage
Opto-coupler
switched
pax. 30 V -, filtered
=
15v
Opto-coupler
open
5
8V
Loading per input
4
IOmA
Control relay outputs
Potential-free
relay contact (switched into groups)
Operating voltage
max.30V-/min.
15V-
Operating current per contact
max. 50 mA
Permissible load
Resistance load;
Inductive
load only with quenching
diode parallel to inductivity
To prevent welding of contacts in the event of short circuiting,
every contact is provided with a current limiting
resistor of 47 ohms in series.
Caution!
Connect control O-volt for inputs and outputs of control to a common groundin
See tiiring
and grounding diagram TNC 151/TNC
155. Operational
ground
2.2
Specific dalta for TNC 151 Q/TNC 155 Q
Nominal values and tolerances
External voltage supply for PLC
Nominal voltage: 24 V, -
Voltage range: 20.4 V to 28.8 V
Furthermore,
superimposed
alternating
voltages with a relative oscillation
width of 10 % - related to the average
DC-voltage value - are permissible.
Circuitry
example:
Definition:
+2&V
g = DC-voltage average: 20.4 _ . . 28.8 V
AU
= Oscillation
width:
-= IO % related to u
k Au
toPLl00B/ll0B
L
u
ov
Binary input signals (EO to E62 and E64 to El261
Nominal voltage:
24 V -,
Voltage range for signal "1":
16.5 V to 30 V
Voltage range for signal "0":
- 3 V to + 4 V
Current range for signal "1":
6.2 mA to 12.6 mA
Please note:
Interference
signalsL1
ms at the PLC-inputs are filtered with a low pass Schmitt-Trigger-input
circuit.
Long
duration interference signals must be faded out via software.
6