Panasonic FP-XH M8N16PD User Manual page 64

Programmable controller
Table of Contents

Advertisement

I/O Allocation
Contact
Target
allocation
axis
X1240
Axis 1
X1241
Axis 2
X1242
Axis 3
X1243
Axis 4
X1244
Axis 5
X1245
Axis 6
Axis 7
X1246
(virtual)
Axis 8
X1247
(virtual)
X1248
-
-X124F
X1250
Axis 1
X1251
X1252
Axis 2
X1253
X1254
Axis 3
X1255
X1256
Axis 4
X1257
X1258
Axis 5
X1259
X125A
Axis 6
X125B
X125C
Axis 7
X125D
X125E
Axis 8
X125F
X1260
-
-X126F
(Note 1): When using the virtual axes, the I/O numbers allocated vary according to the number of virtual axes.
When selecting virtual 1st
axis
When selecting virtual 1st
and 2nd axes
3-16
Name
Description
Turns on when a warning occurs on the corresponding axis.
Warning
The contacts of all axes turn on if all axes have warning.
annunciation
The details of the warning can be confirmed in the warning
annunciation area of the positioning memory.
-
-
RTEX general-
purpose input 1
RTEX general-
purpose input 2
RTEX general-
purpose input 1
RTEX general-
purpose input 2
RTEX general-
purpose input 1
RTEX general-
purpose input 2
RTEX general-
purpose input 1
RTEX general-
Monitor contact for the RTEX general-purpose input connected
purpose input 2
to the corresnponding AMP.
The input status of this contact does not affect on the operations
RTEX general-
of the motor and FP-XH M8N Control Unit.
purpose input 1
RTEX general-
purpose input 2
RTEX general-
purpose input 1
RTEX general-
purpose input 2
RTEX general-
purpose input 1
RTEX general-
purpose input 2
RTEX general-
purpose input 1
RTEX general-
purpose input 2
-
-
The I/O number of "Axis 8 (virtual)" in the above table is allocated to "virtual
1st axis".
The I/O number of "Axis 7 (virtual)" in the above table is allocated to "virtual
1st axis".
The I/O number of "Axis 8 (virtual)" in the above table is allocated to "virtual
2nd axis".