Automatic Operation (Synchronous Control)
12.6.2 Types and Contents of Setting Parameters
The use of the electronic cam requires the following parameter settings.
Parameter name
Electronic cam
use/non-use
Cam pattern
Cam control master
axis period
Cam pattern number to
use
Cam stroke
Advance angle
correction operation
setting
Reference value
Reference speed
Parameter change
time
12-24
Select the use or non-use of the electronic cam function.
When the electronic cam is not used, the electronic cam function will not work, and
output from the electronic clutch will be output as pulses.
The cam pattern is the most fundamental setting for using the electronic cam function.
The cam pattern is set in the cam pattern settings window in the FPWIN GR7
Configuration screen.
The positioning unit converts cam patterns into point data based on the preset cam
curves and resolutions.
Set the number of pulses corresponding to the total phase of the cam pattern used
(one-rotation data on the master axis).
Specify the cam pattern number to be used from cam patterns created.
Set the number of pulses corresponding to the total displacement (100%) of the cam
pattern to use.
Select the use or non-use of the advance angle correction function.
The unit follows the unit system of the master axis.
Setting range: -2,147,482,624 to 2,147,482,624 (The decimal point position is based
on unit systems.)
The unit follows the unit system of the master axis.
Setting range: 1 to 2,147,482,624 (The decimal point position is based on unit
systems.)
Setting range: 1 to 10000 ms
Outline