Panasonic FP-XH M8N16PD User Manual page 536

Programmable controller
Table of Contents

Advertisement

Specifications
Register
Number
Interrupt enable (mask)
DT90025
state (INT0 - 7)
DT90026
Unused
Timer interrupt interval
DT90027
(INT24)
Sampling and tracking
DT90028
interval
DT90029
Unused
DT90030
DT90031
DT90032
Character storage by F149
MSG instruction
DT90033
DT90034
DT90035
Status error occurrence
DT90036
position of FP-X expansion
unit/add-on cassette
DT90037
Work 1 for search instruction
DT90038
Work 2 for search instruction
DT90039
Unused
DT90040
Potentiometer input
DT90041
Unused
-DT90043
DT90044
System job
DT90045
Unused
-DT90051
26-80
Name
The content set by the ICTL instruction is saved.
Monitor with BIN display.
15
13
13
INT0 - INT7: interrupt input X0 - X7
INT0 - INT7: high-speed counter match interrupt CH0
- CH7
The content set by the ICTL instruction is saved.
K0: do not use the timer interrupt.
K1-K3000: 0.1 ms-0.35 s or 0.5 ms-1.5 s
or 10 ms-30 s
K0: changed to sampling performed according to the
SMPL instruction.
K1 - K3000 (× 10ms): 10 ms - 30 s
Stores contents set through the information display
instruction (F149) (character).
Stores the corresponding number upon abnormal
status.
High byte: FP-X expansion unit
Low byte: add-on cassette
(E.g.) The cassette installation part 2 is abnormal for
0001h.
When executing F96 (SRC) instruction, the number
that is consistent with the search data is saved.
When executing F96 (SRC) instruction, a consistent
relative position is saved.
Stores potentiometer value (K0 - K4000).
Read to the data register by the user program, and it
can be used in the analog timer.
Used in the system.
Description
11
7
3
0 (Bit No.)
11
7
3
0
(INT No.)
R
1: Allowed
0: Disable
×
×
×
×
×
W
×
×
×
×
×
×
×
×
×
×
×
×
×
×

Advertisement

Table of Contents
loading

Table of Contents