Panasonic FP-XH M8N16PD User Manual page 173

Programmable controller
Table of Contents

Advertisement

 Dialog box items
Item
Description
When set as the master axis, "Master" will be displayed.
When set as the slave axis, the master axis based on such axis will be
Synchronous
displayed. E.g.) When the axis 2 is set to be a slave following the axis 1
master axis
as the master, "Axis 1" will be displayed in the line of Axis 2".
Axes not used for synchronized control will be displayed as [--------].
Displays the synchronous running function set to the slave axis.
Gear, clutch, cam
Gear+Clutch, Gear+Cam, Clutch+Cam
Synchronized
output
Gear+Clutch+Cam
Axes not used for master axis and synchronized control will be displayed
as [--------].
Displays the set status (synchronous/non-synchronous) of each axis.
Synchronous
Pressing the "Change synchronization" button switches the state between
state
Synchronous and Asynchronous.
Displays the current value of the axes after unit conversion. Click [Home
Current value
position coordinate] to display the value input dialog box to change the
value after home return.
Displays the unit of the position command of each axis set in parameter
Unit
settings.
Home return
Displays the content of the home return setting code registered in the
mode
positioning setting data.
Executes Start/Stop operation of origin
·Click the [Start] button to execute home return, and the button name is
Start/stop
changed to [Stop].
·Press the [Stop] button to execute deceleration stop, and the button
name is changed to [Stop].
Displays the operation state of each axis.
"Operating" (green): The motor is running.
Axis state
"Stopped" (gray): The motor stops.
"Error" (red): An error occurs.
The latest error code is displayed in case of an error. If a recoverable error
Error code
occurs in the control, click the [Clear errors] button to clear the error.
The latest warning code is displayed in case of a warning.
Warning code
Click [Clear warning] to clear the warning.
It allows setting the target speed of home return of different axes set in
Speed rate
parameter settings as 100% to specify the speed multiplier operation.
Click the [Speed rate] button to display the value input dialog box.
10.4 Tool Operation
Related Page
12.1
Synchronous
Control
17.4
Coordinate
17.5 Current
Value Update
14.1 Type of
Home Return
19.3 Table of
Error Codes
19.4 Table of
Warning Codes
10-15

Advertisement

Table of Contents
loading