 Example of operation (1) Speed direct specification, Active table only
Parameter
Change mode selection
Change speed
f
100,000pps
1
A
Speed change request contact turns ON.
B
Only the speed of the table 1 is changed to 150,000 pps.
C
The speeds of the table 2 and 3 do not change.
 Example of operation (2) Speed direct specification, Active table to E point table
(until the completion of the operation)
Parameter
Change mode selection
Change speed
f
100,000pps
1
A
Speed change request contact turns ON.
B
The speeds of all consecutive tables are changed to 150,000 pps.
Setting value
0000H (Active table only)
150,000 (pps)
2
3
Setting value
0001H (Active table to E point table)
150,000 (pps)
2
3
17.6 Target Speed Change Function
f
150,000pps
1
t
A
f
150,000pps
1
t
A
B
C
2
3
B
2
3
t
t
17-13