I/O Allocation
Contact
Target
allocation
axis
Y1100
All axes System stop
Y1101
-
Y1102
All axes
Y1103
All axes
Y1104
-
Y1105
All axes
Y1106
-
Y1107
All axes
Y1108
-
-Y110F
Y111E
-
-Y111F
3-20
Name
Description
Contact for requesting the system stop. When it turns on, all axes will
stop at the deceleration time 0.
-
-
Turn ON this signal for reading cam tables. The cam table of a
Cam table
specified cam pattern number will be read when this signal turns ON.
reading request
After the completion of the reading of cam tables, the cam table
reading done contact (X1102) turns ON.
Turn ON this signal for reading cam tables. The cam table of a
specified cam pattern number will be rewritten when this signal turns
Cam table
ON.
rewriting request
After the completion of the rewriting cam tables, the cam table
rewriting done contact (X1103) turns ON.
-
-
Axis group setting
This contact will turn ON after the axis group settings are changed.
change request
-
-
Turn on this signal when each positioning data (standard area) in the
positioning memory was changed. The positioning data after the
table number starting the recalculation specified in the positioning
memory can be restructured and will be executable by turning on this
Recalculation
signal. When restructuring of the positioning data completes, the
request
recalculation done contact (X1107) turns on.
Note) It is used only when the positioning data has been rewritten by
laddar programs.
-
-
-
-