Panasonic FP-XH M8N16PD User Manual page 511

Programmable controller
Table of Contents

Advertisement

 Clutch setting area
Offset
Name
address
H20
Clutch ON trigger type
Clutch ON edge
H21
selection
H22-H27
Reserved for system
H28
Clutch OFF trigger type
Clutch OFF edge
H29
selection
H2A
Clutch OFF phase ratio
H2B-H2F
Reserved for system
H30
Clutch ON method
H31
Reserved for system
H32
Clutch ON slip method
H33
Clutch ON slip time
H34-H35
Reserved for system
Clutch ON slip curve
H36
selection
H37-H3F
Reserved for system
H40
Clutch OFF method
H41
Reserved for system
H42
Clutch OFF slip method
H43
Clutch OFF slip time
H44-H45
Reserved for system
Clutch OFF slip curve
H46
selection
H47-H4F
Reserved for system
Default
Description
H0
H0: I/O clutch ON request
Set the valid condition of trigger signals.
H0: Level
H0
H1: Leading edge
H2: Trailing edge
H00: I/O clutch OFF request
H00
H11: I/O + Phase after clutch control clutch OFF
Set the valid condition of trigger signals.
H0: Level
H1: Leading edge
H2: Trailing edge
H0
When selecting "H0: Level" for the clutch ON edge
selection (offset address H21), set "H0: Level" in this area
(offset address H29).
Set the ratio for the phase at which the clutch turns OFF
when selecting "I/O + Phase after clutch control" for the
H0
clutch off trigger type.
Setting range: 0-99 (%)
H0: Direct
H0
H1: Slip
H0
H0: Slip time setting
K1
1-10000 ms
H0
H0: Linear
H0: Direct
H0
H1: Slip
H0
H0: Slip time setting
K1
1-10000 ms
H0
H0: Linear
26.4 Positioning Memory
26-55

Advertisement