 Axis group setting area
Offset
Name
Address
HB0
Group-A axis setting
HB1
Group-B axis setting
HB2
Group-C axis setting
HB3
Group-D axis setting
Independent axis
HB4
setting
HB5-HBF
Reserved for system
Default
Set either independent or interpolation for each axis in this area. In
case of interpolation, each axis belongs to any group A to D. For
example, the axes 1, 2 and 3 belong to group A and are 3-axis
interpolation, set the corresponding 3 bits to 1 in the interpolation axis
setting of group A.
The max. number of interpolation in each group is 3, the same axis
cannot be set repeatedly in different groups.
bit
Name
Group attribute of
0
axis 1
Group attribute of
1
axis 2
H0
Group attribute of
2
axis 3
Group attribute of
3
axis 4
Group attribute of
4
axis 5
Group attribute of
5
axis 6
Group attribute of
6
axis 7
Group attribute of
7
axis 8
15-8
Please set the object bit to 1 for independent axis not belonging to the
interpolation group.
bit
Name
0
Attribute of axis 1
1
Attribute of axis 2
2
Attribute of axis 3
3
Attribute of axis 4
H0
4
Attribute of axis 5
5
Attribute of axis 6
Attribute of (virtual)
6
axis 7
Attribute of (virtual)
7
axis 8
15-8
26.4 Positioning Memory
Description
Default Description
0
0
0: Not belong to the interpolation
group
0
1: Belong to the interpolation group.
0
If there are over 4 bits in the group
set to 1, or the same axis being set
0
to 1 repeatedly in other groups, an
error occurs.
Also, an error occurs if an axis that
0
has been set as a virtual axis by
Configurator PM7 is set.
0
0
Default Description
0
0
0
0: Belong to the interpolation group,
or not set as used axes.
0
1: Independent axis (not belonging to
0
the interpolation group).
0
An error may occur when setting the
interpolation group.
0
0
26-17