 Example of operation (For repetitive operations)
When the movement amount change is performed during the positioning repeat operation,
only the movement amount of the active table in an active repeat period is changed.
f
1
2
Repeat: 1st time
f
A
1
2
Repeat: 1st time
Only the movement amount of the table 1 in the first repeat period is
A
changed to 8,000 pls.
The movement amounts of the table 1 in the second and third repeat
B
periods are not changed.
 Auxiliary output when changing movement amounts
Even if the movement amount is changed when the auxiliary output is set in the delay mode,
the auxiliary contact turns ON at the position of the delay ratio to the movement amount
before the change. If the delay ratio is set to100%, however, the auxiliary contact turns ON on
the completion of the operation.
3
1
2
Repeat: 2nd time
3
1
2
Repeat: 2nd time
17.7 Movement Amount Change Function
3
1
2
Repeat: 3rd time
B
3
1
Repeat: 3rd time
3
t
2
3
t
17-21