Automatic Operation (Synchronous Control)

12.5.5 Phase Specification Clutch Off Function

The "phase specification clutch OFF function" is a function for turning off an electronic clutch
at an arbitrarily specified phase. For stopping or starting at the same phase repeatedly, the
control without variance can be performed.
 Phase specification clutch OFF function
When performing the OFF request by the I/O signal, the clutch off operation will be executed
regardless of phase.
Current value
Master axis
Current value
after unit conversion
I/O Y clutch ON request
Connected
I/O X clutch connection
state annunciation
Disconnected
Phase
100%(0%)
Phase after clutch control
Slave axis
(e.g. Rotary cutter)
Using the "phase specification clutch off function" turns a clutch off when the phase reaches
the set phase after the clutch off request by the I/O signal.
Current value
Master axis
Current value
after unit conversion
ON
I/O Y clutch ON request
OFF
Connected
I/O X clutch connection
state annunciation
Disconnected
Phase
100%(0%)
Phase after clutch control
50%
Slave axis
(e.g. Rotary cutter)
(Note 1): The above figure shows the case that the both clutch on request and off request are set to "Level". Also,
either "Rising edge" or "Falling edge" can be selected.
(Note 2):The above figure shows the case that the clutch off setting ratio is set to "0%". It can be set to 0 to 99%.
12-20
ON
OFF
Clutch request is OFF.
Clutch is OFF.
50%
0%
It does not turn OFF until the
phase after clutch control
reaches the set value.
0%
t
t
t
Clutch OFF setting phase
t