Automatic Operation (Synchronous Control)
Setting with tool software
Set in the synchronous control setting dialog box.
Parameter name
Advance angle
correction operation
setting
Reference amount
Reference speed
Parameter change
time
Setting with user programs
The following examples shows the case that the advance angle correction reference value of
1st axis is changed to 50 and the advance angle correction reference speed to 3000.
R0
DF
(
)
F385 PTBLW
R1
DF
(
)
F385 PTBLW
Content specified by
Code
program
Axis no. and synchronous
①
control setting area
Advance angle correction
②
reference amount setting
area
Advance angle correction
③
reference speed setting area
12-40
Overview
Select the use or non-use of the advance angle correction function.
The unit follows the unit system of the master axis.
Setting range: -2,147,482,624 to 2,147,482,624 (The decimal point position is based
on unit systems.)
The unit follows the unit system of the master axis.
Setting range: 1 to 2,147,482,624 (The decimal point position is based on unit
systems.)
Setting range: 1 to 10000 ms
F1 DMV
H4
DT100
①
F0 MV
H4
DT102
①
Value specified by program
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6
H4
H104
K50
DT100
K2
H56
②
K3000
DT102
K2
H58
③
H204
H304
H404
H56
H58
Axis 7
Axis 8
(virtual)
(virtual)
H504
H604
H704