26.4.7 Positioning Operation Change Setting Area (Memory Area No. 5)

Offset
Name
address
Positioning speed
change
H0
Ratio
specification(Override)
Positioning speed
H1
change
Change mode selection
Positioning speed
H2-H3
change
Change speed
H4-H9
Reserved for system
Positioning movement
amount change
HA-HB
Change movement
amount
HC-HF
Reserved for system
Default
Description
Area for setting the change ratio (override) to the command
speed for the positioning speed change. The speed
change request by I/O is not necessary, and the change
K100
becomes valid when the set value (ratio) is set.
Setting range: 1-300 (%)
Area for setting the range of the positioning speed change.
0000H: Active table only
0001H: Active table to E point table (until the completion of
H0
the operation)
In the case of other values, the unit operates as the setting
of 0000H (Active table only).
Area for setting a change speed for changing the
positioning speed. Set using unit system conversion
K100
values.
Setting range: 1-2,147,482,624 (Specified unit system)
Area for setting a change movement amount for changing
the positioning movement amount. Set using unit system
K0
conversion values.
Setting range: K-2,147,482,624-K2,147,482,624
26.4 Positioning Memory