Specifications
 Positioning control starting table number setting area
Offset
Name
Address
Position control
H100
starting table
number of axis 1
Position control
H101
starting table
number of axis 2
Position control
H102
starting table
number of axis 3
Position control
H103
starting table
number of axis 4
Position control
H104
starting table
number of axis 5
Position control
H105
starting table
number of axis 6
Position control
starting table
H106
number of (virtual)
axis 7
Position control
starting table
H107
number of (virtual)
axis 8
 Positioning control area
Offset
Name
Address
Positioning repeat
H108
count of axis 1
Positioning repeat
H109
count of axis 2
Positioning repeat
H10A
count of axis 3
Positioning repeat
H10B
count of axis 4
Positioning repeat
H10C
count of axis 5
Positioning repeat
H10D
count of axis 6
Positioning repeat
H10E
count of (virtual)
axis 7
Positioning repeat
H10F
count of (virtual)
axis 8
26-20
Default
Stores the position control starting table number.
K1
Setting range: 1-600, 10001-10089
Default
Stores the number of times for repeating the operation starting from
the position control starting table number until the E point.
K0
When 255 is stored, the positioning control is repeated unlimitedly
until the operation is stopped.
Setting range: 0-255
Description
Description

Advertisement

Table of Contents
loading

Table of Contents