Panasonic FP-XH M8N16PD User Manual page 497

Programmable controller
Table of Contents

Advertisement

Offset
Name
Address
JOG operation
H29
setting code
JOG operation
H2A
acceleration time
JOG operation
H2B
deceleration time
JOG operation
H2C-H2D
target speed
Default Setting range and description
Sets the mode of the JOG operation.
bit
Name
0
H0
Acceleration/deceler
1
ation pattern setting
15-2
Sets the acceleration/deceleration time when performing the JOG
operation. At the beginning of the JOG operation, accelerates for the
specified acceleration time, decelerates for specified deceleration time
K100
when the starting contact of the JOG operation turns off, and stops.
Setting range: 0-10,000 (ms)
Any other settings will be errors.
Set the target speed for performing the JOG operation. After starting
the JOG operation, accelerates to the target speed while the starting
contact of the JOG operation is on. After reaching the target speed,
operates at the target speed.
Range: 1-2,147,482,624
K1000
Any other settings will be errors. The ranges vary depending on the
unit settings as below.
pulse: 1-2,147,482,624 pps
μm: 1-2,147,482,624 μm/s
inch: 0.001-2,147,482.624 inch/s
degree: 0.001-2,147,482.624 rev/s
26.4 Positioning Memory
Default
Description
0: Linear
acceleration/deceleration
0
1: S-shaped
acceleration/deceleration
26-41

Advertisement

Table of Contents
loading

Table of Contents