Manual Operation
(JOG Operation)

13.1 Setting and Operation of JOG Operation

The following example is explained with the JOG operation of axis-1. Settings are made in
pulses.
Reverse JOG
Ball screw
(-) side
 Settings
Parameters required for the JOG operation of the positioning unit is set in the positioning
setting menu of the programming tool.
Items
Acceleration/deceleration pattern
Acceleration time (ms)
Deceleration time (ms)
Target speed
 Operation diagram
f [pps]
10000
Forward JOG contact Y1160
Reverse JOG contact Y1161
BUSY flag X1130
Operation done flag X1140
 Operation of each contact
• The BUSY flag (X1130), which indicates that the motor is running, will turn ON when the
positioning control starts, and it will turn OFF when the operation completes.
• The operation done flag (X1140), which indicates the completion of operation, will turn ON
when the current operation is completed, and it will be held until the next positioning control,
JOG operation, home return, or pulser operation starts.
13-2
Forward JOG
Table
0: Linear acceleration/deceleration
100 ms
100 ms
10000 pps
Forward
100
(+) side
Setting example
Reverse
100
100
t [ms]