Code
Name
Cam pattern table
B110H
reading error
warning
Cam pattern table
B1111H
rewriting error
warning
Recalculation
B304H
exception
warning
Description
The operation for the cam
pattern table reading request
ended abnormally as an
incorrect value was set or the
execution condition was not
satisfied.
The operation for the cam
pattern table rewriting request
ended abnormally as an
incorrect value was set or the
execution condition was not
satisfied.
Error occurs during
recalculation
19.4 Table of Warning Codes
Object
Recovery
All axes
All axes
Each
axis
Measures
・Confirm the setting values of the
parameters required for reading cam
patterns.
・Confirm if any axes are in
synchronous operation. If any, cancel
the synchronous operation and read
the cam pattern tables.
* The details about the cause of the
occurrence of this warning are stored
in the "cam pattern reading result"
area of the positioning memory.
・Confirm the setting values of the
parameters required for rewriting cam
patterns.
・Confirm if any axes are in
synchronous operation. If any, cancel
the synchronous operation and
rewrite the cam pattern tables.
* The details about the cause of the
occurrence of this warning are stored
in the "cam pattern rewriting result"
area of the positioning memory.
Please check the parameters of
the axes and the settings of the
interpolation group.