Panasonic FP-XH M8N16PD User Manual page 241

Programmable controller
Table of Contents

Advertisement

 Procedure of reading cam pattern data
Step
Operation by user programs and unit operation
Set a cam pattern number to be read out to the cam pattern editing area.
Turn on the came table reading request (Y1102) from a ladder program.
On the completion of reading, turn on the cam pattern reading completion annunciation (X1102) after
storing a response code in "Cam table reading result".
Once the cam table reading request (Y1102) turns off, the unit turns off the cam pattern reading
completion annunciation flag (X1102).
Cam table reading request
(Y1102)
Cam table reading completion
annunciation (X1102)
Cam table edit no.
Cam table reading result
 Related positioning parameter
Offset
Area
address
Cam pattern
editing area
58H
(No.3)
ON
OFF
ON
OFF
Read cam pattern no.
Name
Default
Cam pattern
H0
reading result
12.6 Electronic Cam Function
0000h (Nomal completion)
The cam table data of the specified number
is stored in the cam pattern editing area.
●Cam pattern editing area
No. of sections
Section n Start phase
Displacement
Cam curve no.
Description
・Stores the result of reading processing
(response code).
[Range] (Hexadecimal)
0000H: Normal end
Other than 0000H: Abnormal end
12-33