Panasonic FP-XH M8N16PD User Manual page 549

Programmable controller
Table of Contents

Advertisement

Code
Name
A position control
E44
operation error
occurred
Operation error
E45
occurred
Motion part AMP
E47
communication error
Abnormal system
E48
register setting
Abnormal expansion
E49
power sequence
Abnormal battery
E50
(battery fall off or
voltage reduced)
E100-
E199
Self-diagnosis error set
by F148
E200-
E299
Run
Error content and handling method
 Parameter settings may be incorrect, or there was a limit
error.
 Check if the parameters are within the range that can be
Select
specified.
 Check the AMP error code for the channel on which the
positioning operation error occurs and the content on the data
monitor of Configurator PM7.
 An operation error cannot be performed occurred.
 The operation error address can be confirmed by one of the
Select
special register DT90017 and DT90018. You can use the tool
software to confirm it by the [Operation Error] button in the
status display dialog box.
 An error in the communication with the servo amplifier
occurred.
Select
 Check the connection.
 Check the AMP error code on the data monitor of
Configurator PM7.
 The settings of the system register are abnormal. Check the
settings again. Example) If the data register and internal relay
ranges set by the system register No. 0 and No. 1 are not
matched with the setting of the system register No. 7 and No. 8
Stop
hold / non-hold area and the setting of the system register No.
running
416-No. 423 universal communication buffer area, an error will
occur.
 Verify the number of the system register through the special
register DT90007.
 The power of the expansion Unit is turned on later than the
Stop
control unit. Make sure it is powered on before the control unit
running
or at the same time.
 The backup battery voltage is lower than the specified
voltage, or the control unit is not connected to the battery.
Verify the backup battery, pay attention to the replacement and
continues
connection work.
operation
 You can set whether to notify the self-diagnostic error
through the system register No. 4.
Stop
 An error set by the application instruction F148 occurred.
 Handle it according to the detection conditions set.
Operation
continues
26.8 Table of Error Codes
26-93

Advertisement

Table of Contents
loading

Table of Contents