show running-config uplink-state-group

Display the current configuration of one or more uplink-state groups.
S4810
Syntax
show running-config uplink-state-group [group-id]
Parameters
group-id
Defaults
none
Command
Modes
Command
This guide is platform-specific. For command information about other platforms,
History
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version 9.2(0.0)
Version
8.3.19.0
Version
8.3.12.0
Version 8.4.2.3
Example
Dell#show running-config uplink-state-group
!
no enable
uplink state track 1
downstream GigabitEthernet 0/2,4,6,11-19
upstream TengigabitEthernet 0/48, 52
upstream PortChannel 1
!
uplink state track 2
downstream GigabitEthernet 0/1,3,5,7-10
upstream TengigabitEthernet 0/56,60
Related
Commands
Uplink Failure Detection (UFD)
Displays the current configuration of all uplink-state groups
or a specified group. The valid group-id values are from 1 to
16.
EXEC
EXEC Privilege
Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
Introduced on the S4820T.
Introduced on the S4810.
Introduced on the S-Series S50.
show uplink-state-group
uplink-state group or all groups.
uplink-state-group
— creates an uplink-state group and enables the tracking of
upstream links.
— displays the status information on a specified
1683