# Switch configuration messages
local7.info
Note:
Note the following items when you edit file "/etc/syslog.conf".
A note must start in a new line, starting with a "#" sign.
In each pair, a tab should be used as a separator instead of a space.
No space is permitted at the end of the file name.
The device name (facility) and received log information severity specified in file
"/etc/syslog.conf" must be the same with those corresponding parameters
configured in commands info-center loghost and info-center source. Otherwise,
log information may not be output to the log host normally.
Step 3: After the log file "information" is created and the file "/etc/syslog.conf" is
modified, execute the following commands to view the process ID of the system
daemon "syslogd", stop the process, and then restart the daemon "syslogd" in the
background with the "-r" option.
# ps -ae | grep syslogd
147
# kill -9 147
# syslogd -r &
In case of Linux log host, the daemon "syslogd" must be started with the "-r" option.
After all the above operations, the switch can record information in the corresponding
log file.
Note:
Through combined configuration of the device name (facility), information severity level
threshold (severity), module name (filter) and the file "syslog.conf", you can sort
information precisely for filtering.

1.4.3 Log Output to the Console

I. Network requirements
The switch sends the following information to the console: the log information of the two
modules ARP and IP, with severity higher than "informational".
/var/log/Switch/information