Operation Manual – HWPing
H3C S3100-52P Ethernet Switch
Switch A sends an SNMP query message to Switch B (SNMP Agent) to it receives a
response from Switch B.
II. Network diagram
Figure 1-7 Network diagram for the SNMP test
III. Configuration procedure
Configure SNMP Agent (Switch B):
# Start SNMP agent and set SNMP version to V2C, read-only community name to
public, and read-write community name to private.
<Sysname> system-view
[Sysname] snmp-agent
[Sysname] snmp-agent sys-info version v2c
[Sysname] snmp-agent community read public
[Sysname] snmp-agent community write private
Note:
The SNMP network management function must be enabled on SNMP agent before
it can receive response packets.
The SNMPv2c version is used as reference in this example. This configuration may
differ if the system uses any other version of SNMP. For details, see SNMP –
RMON Operation Manual.
Configure HWPing Client (Switch A):
# Enable the HWPing client.
<Sysname> system-view
[Sysname] hwping-agent enable
# Create a HWPing test group, setting the administrator name to administrator and
test tag to snmp.
[Sysname] Hwping administrator snmp
# Configure the test type as snmp.
[Sysname-hwping-administrator-snmp] test-type snmpquery
# Configure the destination IP address as 10.2.2.2.
Chapter 1 HWPing Configuration