Operation Manual – AAA
H3C S3100-52P Ethernet switch
Enter system view
Create a HWTACACS
scheme and enter its view
Set the response timeout
time of TACACS servers
Set the time that the
switch must wait before it
can restore the status of
the primary server to
active
Set the real-time
accounting interval
Caution:
To control the interval at which users are charge in real time, you can set the
real-time accounting interval. After the setting, the switch periodically sends online
users' accounting information to the TACACS server at the set interval.
The real-time accounting interval must be a multiple of 3.
The setting of real-time accounting interval somewhat depends on the performance
of the TACACS client and server devices: A shorter interval requires higher device
performance.
To do...
system-view
hwtacacs scheme
hwtacacs-scheme-name
timer response-timeout
seconds
timer quiet minutes
timer
realtime-accounting
minutes
Use the command...
2-31
Chapter 2 AAA Configuration
Remarks
Required
By default, no
HWTACACS scheme
exists.
Optional
By default, the response
timeout time is five
seconds.
Optional
By default, the switch
must wait five minutes
before it can restore the
status of the primary
server to active.
Optional
By default, the real-time
accounting interval is 12
minutes.