Operation Manual – GVRP
H3C S3100-52P Ethernet Switch
Table 1-2 Relations between the timers
Hold
Join
Leave
LeaveAll
Note:
The following are recommended GVRP timer settings:
GARP hold timer: 100 centiseconds (1 second)
GARP Join timer: 600 centiseconds (6 seconds)
GARP Leave timer: 3000 centiseconds (30 seconds)
GARP LeaveAll timer: 120000 centiseconds (2 minutes)

1.2.4 Configuring GVRP Port Registration Mode

Follow these steps to configure GVRP port registration mode:
Enter system view
Timer
10 centiseconds
This lower threshold is
greater than or equal to
twice the timeout time of
the Hold timer. You can
change the threshold by
changing the timeout time
of the Hold timer.
This lower threshold is
greater than twice the
timeout time of the Join
timer. You can change the
threshold by changing the
timeout time of the Join
timer.
This lower threshold is
greater than the timeout
time of the Leave timer.
You can change threshold
by changing the timeout
time of the Leave timer.
To do ...
system-view
Lower threshold
Use the command ...
1-7
Chapter 1 GVRP Configuration
Upper threshold
This upper threshold is
less than or equal to
one-half of the timeout
time of the Join timer. You
can change the threshold
by changing the timeout
time of the Join timer.
This upper threshold is
less than one-half of the
timeout time of the Leave
timer. You can change the
threshold by changing the
timeout time of the Leave
timer.
This upper threshold is
less than the timeout time
of the LeaveAll timer. You
can change the threshold
by changing the timeout
time of the LeaveAll timer.
32,765 centiseconds