Operation Manual – Stack-Cluster
H3C S3100-52P Ethernet Switch
Serving as the management device, the S3100-52P switch manages the two member
devices. The configuration for the cluster is as follows:
The two member devices connect to the management device through Ethernet
1/0/2 and Ethernet 1/0/3.
The management device connects to the Internet through Ethernet 1/0/1.
Ethernet 1/0/1 belongs to VLAN 2, whose interface IP address is 163.172.55.1.
All the devices in the cluster share the same FTP server and TFTP server.
The FTP server and TFTP server use the same IP address: 63.172.55.1.
The NMS and logging host use the same IP address: 69.172.55.4.
II. Network diagram
FTP/TFTP Server
63.172 .55.1
Cluster
Figure 2-4 Network diagram for HGMP cluster configuration
III. Configuration procedure
1)
Configure the member devices (taking one member as an example)
# Enable NDP globally and on Ethernet 1/0/1.
<Sysname> system-view
[Sysname] ndp enable
[Sysname] interface Ethernet 1/0/1
[Sysname-Ethernet1/0/1] ndp enable
[Sysname-Ethernet1/0/1] quit
# Enable NTDP globally and on Ethernet 1/0/1.
[Sysname] ntdp enable
[Sysname] interface Ethernet 1/0/1
[Sysname-Ethernet1/0/1] ntdp enable
Internet
Eth 1/0/1
Management
device
Eth 1/0/3
Eth 1/0/2
Eth 1/0/1
Member device
MAC: 000f.e201. 0011
MAC: 000f. e201. 0012
SNMP/logging host(NMS)
69.172.55.4
VLAN-interface 2
163.172 .55.1
Eth 1/0/1
Member device