H3C S3100-52P Ethernet switch
Connect the serial port of your PC/terminal to the console port of the switch, as
shown in
Figure 3-4 Diagram for establishing connection to a console port
Launch a terminal emulation utility (such as Terminal in Windows 3.X or
HyperTerminal in Windows 95/Windows 98/Windows NT/Windows 2000/Windows
XP) on the PC terminal, with the baud rate set to 9,600 bps, data bits set to 8,
parity check set to none, and flow control set to none.
Turn on the switch and press Enter as prompted. The prompt (such as <H3C>)
appears, as shown in the following figure.
Figure 3-5 The terminal window
Perform the following operations in the terminal window to assign IP address
202.38.160.92/24 to VLAN-interface 1 of the switch.
<Sysname> system-view
[Sysname] interface Vlan-interface 1
[Sysname-Vlan-interface1] ip address 202.38.160.92 255.255.255.0
2)
Perform Telnet-related configuration on the switch. Refer to
with Authentication Mode Being
Mode Being
Scheme
3)
Connect your PC/terminal and the Switch to an Ethernet, as shown in
Make sure the port through which the switch is connected to the Ethernet belongs
to VLAN 1 and the route between your PC and VLAN-interface 1 is reachable.
Figure 3-4
Password, and
Telnet Configuration with Authentication Mode Being