Rep 12 Engine Shield Assembly - Xerox WORKCENTRE 3119 Service Manual

Hide thumbs Also See for WORKCENTRE 3119:
Table of Contents

Advertisement

Repairs/Adjustments
REP 12 Engine Shield
Assembly
Parts list on PL 1
WARNING
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1. Remove the Scan Assembly. (Refer to
REP 6)
Remove the Fuser Connectors. (Refer to
REP 9, Step 2)
Remove the Toner Fan Connector. (REP
11, Step 2)
2. Remove 11 screws,Figure 1.
Figure 1
4-18
3. Tilt the Engine Shield Assembly to the left
and remove the Engine Shield Assembly,
Figure 2.
4. Disconnect all connectors from the Main
PBA and SMPS/HVPS.
06/06
Figure 2
WorkCentre 3119