Setting Up The Network (Setup Is Required When Communicating With The Is.) - JUKI KE-3010 Maintenance Manual

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

13-2-3. Setting Up the Network
To use the communication between the KE-3010/3020V/3020VR and the IS, it is absolutely
necessary to set up the network.
<Setting procedures>
Setting up the TCP/IP
Setting up a shared folder
Registering a user
Cautions on TCP/IP setup
If your company determines the rules about IP address setup, you must follow the
instructions given by the network administrator of your company.
If no rules are specified, set an IP address, which has not been set in other main unit
connected to the IS.
The IP address has been set at "192.168.100.100" and the subnet mask has been set at
"255.255.255. 0" before shipment from the factory.
When the coplanarity option is set to construct the network of the IS, it is necessary to set
an address other than "192.168.0.XXX" for the IP address on the mounter CPU board side.
This rule also applies when other KE-3000-series machine equipped with the coplanarity
option that makes up the network is already set.
[Reason]
The KE-3000-series coplanarity CPU board performs the communication
between "mounter CPU board" ⇔ "coplanarity CPU board" and that between
"coplanarity CPU board" ⇔ "coplanarity sensor" through the Ethernet. The IP
addresses of the coplanarity sensor and coplanarity CPU board use fixed
addresses of the "192.168.0.XXX" group. Therefore, when a network is
constructed to connect the IS or others, it is necessary to assign IP addresses
of different group to the port (LAN1) of the coplanarity CPU board so that the IP
addresses of the coplanarity sensors do not conflict with each other. (Set the IP
address shown in the box.)
Use externally
mounted keyboard
and mouse to set the
IP address of the
coplanarity CPU.
For details about how to set the IP address of the coplanarity CPU of the mounter equipped
with the coplanarity option, see section 13-4, Coplanarity Sensor (Optional) and section
13-4-2, Changing the IP address of the coplanarity CPU.
Maintenance Guide
(Setup is required when communicating with the IS.)
Default settings
Mounter CPU board (LAN1)
Coplanarity CPU board (LAN1)
Fixed settings
Coplanarity CPU board (LAN2)
Coplanarity sensor
Mounter 1
Coplanarity
sensor
Coplanarity
CPU
LAN2
LAN1
HAB
To IS PC, etc.
Mounter 2
Coplanarity
sensor
Mounter
Coplanarity
CPU
CPU
LAN1
HAB
13-13
192.168.100.100
192.168.100.101
192.168.0.100
192.168.0.XXX
Mounter
CPU
LAN2
LAN1
LAN1
HAB
To other mounter
Rev. 2.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-3020vKe-3020vr