3-3-2. Adjusting the HMS Height
Move the HMS sensor to a point above the calibration block. Loosen the SEMS cap bolts
two locations and adjust the distance between the bottom surface of the height sensor and the
top surface of the calibration block to a specified value of 50 ± 0.2 mm. After the distance has
been adjusted to a specified level, secure the height sensor with the SEMS cap bolts
locations.
SEMS cap bolt
CAL block top surface
After the sensor height has been adjusted, input the MS parameters related to the bad mark
sensor offset. For details about how to input MS parameters, see "MS Parameters".
CAUTION
Maintenance Guide
Figure 3-3-2-1 Adjusting the HMS Height
To prevent any personal injury, do not put your hand inside the
machine or your face or head close to the machine during operation
of the touch panel and/or HOD.
40113694: HMS_ASM
3-7
Rev. 1.0