JUKI KE-3010 Maintenance Manual page 289

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

4) Assemble a new sensor.
Secure a new sensor to the sensor base temporarily
using the fixing screws 5.
Insert the (jig) reference pins 7 into the reference hole
positions shown in the Fig. to make the positioning of the
sensor.
Tighten the fixing screws 5 firmly and pull out the (jig)
reference pins 7.
When pulling out the reference pin, cover it with a cloth
rag and pull it out with long-nose pliers.
For the reference hole, use the KE-3010 (lower portion)
or KE-3020V/3020VR (upper portion).
5 SL6082092TN × 4
6 40097422 × 1
7 PH0600282U0 (jig) × 2
5) Obtain the MS Parameters again.
After the sensor has been replaced, it is absolutely necessary to obtain the MS parameters
again. Start up the MS parameter and select [VCS offset setup]-[Coplanarity offset] to obtain
[Assembling position] and [Focus height].
Jig to be used:
Nozzle to be used: 508-nozzle
Maintenance Guide
40098180
Coplanarity adjustment jig
13-44
6
5
Sensor base
Rev. 2.0