JUKI KE-3010 Maintenance Manual page 244

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

Adjusting the ETF feeder float sensor
1) Set the bulk feeder at the left, center, and right positions of the bank to check that the
sensor is not turned OFF.
2) Insert/remove the ETF into/from the left, center, or right of the electric bank and move it
within a play of the rail to check whether or not the sensor is turned OFF.
3) Set the ETF8S at the same positions as described in step 1) and open the top cover by
hand to check that the sensor is turned OFF when the top cover is raised 10 mm or less.
Figure 12-2-5 Adjusting the Feeder Float Sensor
Figure 12-2-6 Adjusting the Feeder Float Sensor
∗ If the sensor is not turned OFF even though the font cover is opened, the sensor mounting
position may deviate in the Y-direction.
If this occurs, loosen the sensor mounting screws and move the sensor back and forth.
Maintenance Guide
cover
Front
ETF
Move the sensor back and forth.
Light
emission
12-11
(Transport side)
Light
receiving
Rev. 2.0