Replacing The Cover Open Switch - JUKI KE-3010 Maintenance Manual

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

11-3. Replacing the Cover Open Switch

1) Disconnect the connector of the cover open switch
(CN8) and that on the rear from the relay connector (CN7).
2) Cut the tie-up band and remove the washer assembled hexagon socket head cap bolt
replace the cover open switch main unit
3) Reassemble the components in the reverse order of disassembly.
∗ After assembling, check that the safety switch key
into the cover open switch properly.
To ensure the safety, this safety switch key uses the special screw (key screw
cannot be removed easily. To make the adjustment, the dedicated wrench (Allen wrench
(40080491)) is required.
A
4
Safety cover
5
No.
40002254
SL6042042TN
NM3040520SF
HA005280010
40080490
Maintenance Guide
Part No.
COVER_OPEN_SW_CABLE_ASM
SCREW
FLANGE NUT M4
SAFETY_SWITCH_KEY
KEY_SCREW
on the front from the operation board
.
mounted on the safety cover is inserted
2
Part name
11-5
) so that it
A
B
B
1
3
Q'ty per machine
2
4
4
2
4
Rev. 2.0
to
1