17-2. Adjusting the Light Quantity of the Offset Placement after Solder
Screen-Printing Light
<Procedure>
1) Manually check to make sure that both the s Offset Placement After Solder
Screen-Printing light and the OCC light go on.
2) Implement the "OCC light quantity adjustment" of the MS parameter.
When using an optional soldering light, adjust the reference current value so that the
LGET output result of (soldering light) AVE_LVL is 210±2.
Substitute the obtained reference current value into the following formula and save the
calculated value to the reference current value.
Calculation formula: Reference current value × 2 = Value to be saved
∗ The jig to be used for adjustment of the soldering light is the same jig which is used for
adjustment of the standard angle light and vertical light.
Maintenance Guide
17-2
Rev. 2.0