Parallelism to X-axis: 0.05
mm or less
8) Turn ON the machine, start up the MS parameter, and select [Offset setup (O)]-[CVS offset
(S)] to obtain the CVS offset values again.

19-2. Replacing the PCB

1) Follow steps 1) and 2) in previous section 19-1 to detach the CVS_COVER.
2) Disconnect the connector and remove the spacers and screw to replace the CVS PCB.
Connector
40095117
CVS PCB ASM
3) Reassemble the CVS_COVER that has been detached. When the CVS unit has been
detached, perform steps 7) and 8) stated in previous section 19-1.
Maintenance Guide
19-4
HX00354000G
SPACER
(4 locations)
SL4030681SC
SCREW M3 L=6
(1 location)
Rev. 2.0